| Home | E-Submission | Sitemap | Editorial Office |  
top_img
Audiol > Volume 3(2); 2007 > Article
Audiology 2007;3(2): 148-150.
Published online: December 31, 2007.
doi: http://doi.org/10.21848/audiol.2007.3.2.148
두 채널 이음향방사 검사의 유용성에 관한 연구
조수진1, 조소현1, 이은규2
1대불대학교 간호복지치료학부 언어치료청각학과
2대불대학교 보건대학원 청각학전공
A Study on the Usefulness of Two-Channel OAE System
Soo-Jin Cho1, So-Hyun Cho1, Eun-Gyu Lee2
1Department of Speech Pathology & Audiology, Faculty of Nursing, Welfare & Therapy, Daebul University, Yeongam, Korea
2Speech Pathology & Audiology, Graduate School of Public Health, Daebul University, Yeongam, Korea
Correspondence  Soo-Jin Cho ,Tel: (061) 469-1482, Fax: (061) 469-1317, Email: sj2434@mail.daebul.ac.kr
Received: October 21, 2007;  Accepted: November 29, 2007.  Published online: December 31, 2007.
ABSTRACT
It is now generally accepted that otoacoustic emission (OAE) was an objective and non-invasive test for the functional exploration of active micro-mechanical characteristics of outer hair cells. And OAE has been widely used as a tool for hearing screening test. So the purpose of this study was to evaluate of the usefulness of two-channel OAE system as a hearing screening test. Transientevokedotoacoustic emission (TEOAE) and distortion product otoacoustic emission (DPOAE) were measured in each ear of eighteen adults (11 males;7 females) with normal hearing with ILO v6 two-channel OAE system. Results as followed. TEOAE and DPOAE amplitudes with unilateral stimulation were larger than with bilateral stimulation except for DPOAE amplitudes of the right ear. But there were not the significant difference for unilateral and bilateral stimulations as a whole. Therefore this study showed that two-channel OAE system will be usefully applied as a hearing screening test.
Key Words: Otoacoustic emission·Unilateral and bilateral stimulations·Two-channel OAE system.
중심단어: 이음향방사· 일측성 및 양측성 자극· 두 채널 이음향방사 시스템.
TOOLS
PDF Links  PDF Links
Full text via DOI  Full text via DOI
Download Citation  Download Citation
  Print
Share:      
METRICS
0
Crossref
0
Scopus
2,194
View
6
Download
Related article
The Study on the Validation of AMA Pure-Tone Audiometer  2009 December;5(1)
Editorial Office
RN. 8602, Hallym University,
1 Hallymdaehak-gil, Chuncheon-si, Gangwon-do 24252, Korea
TEL: +82-70-8274-4268   FAX: +82-33-256-3420   E-mail: audiologykorea@gmail.com
About |  Browse Articles |  Current Issue |  For Authors
Copyright © Korean Academy of Audiology.                 Developed in M2PI