| Home | E-Submission | Sitemap | Editorial Office |  
top_img
Audiol > Volume 9(1); 2013 > Article
Audiology 2013;9(1): 25-32.
Published online: June 30, 2013.
doi: http://doi.org/10.21848/audiol.2013.9.1.25
건청인과 감각신경성난청 성인의 청력역치에 따른 음량증가의 변화
박유진1, 이경원2
1분당재생병원
2한림국제대학원대학교 청각학과
A Changes of Loudness Growth as a Function of Hearing Threshold Level in Adults with Normal and Sensorineural Hearing Loss
Yoo Jin Park1, Kyoung Won Lee2
1Pundang Jesaeng General Hospital, Sungnam City, Kyunggi-do, Korea
2Department of Audiology, Hallym University of Graduate Studies, Seoul, Korea
Correspondence  Kyoung Won Lee ,Tel: (02)2051-4951, Fax: (02)3453-6618, Email: leekw@hallym.ac.kr
Received: April 27, 2013; Revised: June 11, 2013   Accepted: June 18, 2013.  Published online: June 30, 2013.
ABSTRACT
The purpose of this study was to examine changes in the most comfortable level (MCL) and the uncomfortable level (UCL) depending on hearing threshold level (HTL) by investigating loudness growth among persons with normal hearing (NH) and sensorineural hearing loss (SNHL) at 500 Hz and 3,000 Hz. Based on the results, this study intended to provide useful data to calculate gain or frequency response curve and SSPL90 or OSPL90 of hearing aid that was used by Koreans with hearing loss. The NH group consisted of 17 persons (17 ears) in total who had the pure tone threshold average of 20 dB HL or less and who were 23-33 years old (average: 27.9 years, SD: 4.0 years). The SNHL group consisted of 117 persons (161 ears) in total who had the HTL of 40-75 dB HL at 500 Hz or 3,000 Hz and who were 19-78 years old (average: 55.1 years, SD: 15.4 years). As for presented tone, 5% frequency-modulated tone was used at 500 Hz and 3,000 Hz. Based on the results of study by Allen (1990), loudness category (LC) for loudness growth test was divided to 7 LCs before the HTL of 40-75 dB for NH and SNHL was divided by 5 dB interval at 500 Hz and 3,000 Hz. The results of this study were as follows. First, at 500 Hz and 3,000 Hz, the MCL of NH was 51.5 and 56.8 dB HL while the UCL was 88.5 dB HL and 88.7 dB HL. Consequently, the MCL at 3,000 Hz was found to be higher by 5.3 dB (p < .05). Second, the MCL and the UCL of SNHL persons increased as a function of the HTL. However, slope of regression equation was low in the order of the HTL, the MCL and the UCL. Therefore, it was confirmed that dynamic range became narrow according to increase in the HTL. Third, the MCL showed the higher correlation with the HTL than the UCL. This study was meaningful in that the study intended to measure loudness growth of Koreans with NH and SNHL. The results of this study are expected to have influences on development of hearing aid fitting formula for Koreans with hearing loss.
Key Words: Sensorineural hearing loss (SNHL), Hearing threshold level(HTL), Most comfortable level(MCL), Uncomfortable level(UCL), Loudness growth test(LGT).
중심단어: 감각신경성난청, 청력역치, 쾌적수준, 불쾌수준, 음량증가검사
Editorial Office
RN. 8602, Hallym University,
1 Hallymdaehak-gil, Chuncheon-si, Gangwon-do 24252, Korea
TEL: +82-70-8274-4268   FAX: +82-33-256-3420   E-mail: audiologykorea@gmail.com
About |  Browse Articles |  Current Issue |  For Authors
Copyright © Korean Academy of Audiology.                 Developed in M2PI